Infant Incubator M10
Infant Incubator M10
Infant Incubator M10
Infant Incubator M10
Infant Incubator M10
Infant Incubator M10
Infant Incubator M10
  • Series:

    Infant Incubator

  • Size:

    1026×560×1340mm

  • Description:

    The microprocessor-based servo-controlled temperature system ensures exceptional thermal stability in Air Control Mode. With independent LED displays for set temperature, air temperature, heating power, and timer, clinicians gain real-time visibility. Triple over-temperature protection—featuring individual cut-off devices—exceeds safety standards, while automated alarms (audible/visual) activate for critical events

  • Ingredients:

  • Function:

    Microprocessor based servo controlled temperature system

Infant Incubator M10
Infant Incubator M10
Infant Incubator M10
Infant Incubator M10
Infant Incubator M10
Infant Incubator M10
Infant Incubator M10
  • Series:

    Infant Incubator

  • Size:

    1026×560×1340mm

  • Description:

    The microprocessor-based servo-controlled temperature system ensures exceptional thermal stability in Air Control Mode. With independent LED displays for set temperature, air temperature, heating power, and timer, clinicians gain real-time visibility. Triple over-temperature protection—featuring individual cut-off devices—exceeds safety standards, while automated alarms (audible/visual) activate for critical events

  • Ingredients:

  • Function:

    Microprocessor based servo controlled temperature system

Infant Incubator M10: Advanced Neonatal Care Solution

Precision Temperature Control & Safet

The microprocessor-based servo-controlled temperature system ensures exceptional thermal stability in Air Control Mode. With independent LED displays for set temperature, air temperature, heating power, and timer, clinicians gain real-time visibility. Triple over-temperature protection—featuring individual cut-off devices—exceeds safety standards, while automated alarms (audible/visual) activate for critical events:

  • Power failure
  • Temperature deviation (±3.0°C)
  • Probe malfunction (±0.5°C control accuracy)
  • Fan failure
  • Over-temperature emergencies 

    Infant Incubator M10

Optimized Infant Environment

  • Adjustable Humidity: Continuously regulated to support neonatal respiratory health.
  • Ergonomic Design: Infant bed inclination (±12°) enhances comfort and medical access.
  • Low-Noise Operation: ≤50 dB(A) fans minimize environmental stress.
  • Rapid Warm-Up: Reaches target temperature in ≤45 minutes (range: 25.0°C–39.0°C).

Functional Design Features

  • Hood Configuration: Single-wall hood with 4 operating windows, 2 iris ports, and 4 infusion seals.
  • Accessories: Integrated IV pole with tray (325×255mm) and oxygen inlet.
  • Mattress: Spacious 630×370×20mm surface with ≤58°C uniformity.
  • Data Connectivity: RS232 port for monitoring integration.

Technical Specifications

| Parameter | Value |
|-------------------------|--------------------------------|
Power Supply | AC110/220V 50/60Hz, ≤550VA |
Temperature Range | 20.0°C–42.0°C (display) |
Mattress Size | 630×370×20mm |
Noise Level | ≤50 dB(A) |
Product Dimensions | 1026×560×1340mm |
Weight | 105kg (net) / 120kg (gross) |
Operating Environment | Humidity: 30–75% RH, Pressure: 700–1060hpa |


Optional Enhancements

  • Upper/Lower LED Phototherapy Units (H60/H80)
  • Height-Adjustable Touch Screen
  • Double-Wall Hood & X-Ray Cassette Holder

Transport & Storage

  • Temperature: -20°C to +55°C
  • Humidity: ≤95% RH
  • Pressure: 500–1060hPa

The Infant Incubator M10 combines rigorous safety protocols, responsive environmental control, and modular flexibility, delivering unparalleled reliability for critical neonatal care. Engineered to operate seamlessly in diverse clinical settings, it sets a new standard in infant thermal management.